BGTMX - CAREFREE RECHARGEABLE BATTERY CFM 12V25
- MSDS: BGTMX
- Manufacturer: EAGLE PINCHER INDUSTRIES
- Product Name: CAREFREE RECHARGEABLE BATTERY CFM 12V25
- National Stock Number: 6140-01-245-8350
Product Identification
Product ID:CAREFREE RECHARGEABLE BATTERY CFM 12V25
MSDS Date:10/21/1988
FSC:6140
NIIN:01-245-8350
MSDS Number: BGTMX
Responsible Party
SENECA, MO 64865
Emergency Phone: 417-776-2256
Info Phone: 417-776-2256
Cage: 81855
Contractor
Telephone: 417-623-8000
Cage: 81855
Ingredients
SULFURIC ACID (SARA III)
CAS: 7664-93-9
RTECS: WS5600000
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3; 9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
LEAD MONOXIDE (LEAD OXIDE YELLOW)
CAS: 1317-36-8
RTECS: OG1750000
OSHA PEL 0.05 MG/M3 (PB)
ACGIH TLV: 0.15 MG/M3(PB); 8990
LEAD (SARA III)
CAS: 7439-92-1
RTECS: OF7525000
OSHA PEL 0.05 MG/M3;1910.1025
ACGIH TLV: 0.15 MG/M3;DUST 9192
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
POLYMER CASE
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:NO OSHA:NO
Health Hazards Acute and Chronic:PRODUCT IS AN ARTICLE WHICH UNDER
NORMAL USE IS NON-HAZARDOUS. HOWEVER UNDER CERTAIN UNUSUAL
CONDITIONS PERSONS MAY BE EXPOSED TO TOXIC LEAD,CORROSIVE SULFURIC
ACID,AND/OR EXPLOSIVE HYDROGEN.
Explanation of Carcinogenicity:NTP LISTS LEAD ACETATE & PHOSPHATE AS
ANIMAL CARCINOGENS WITHOUT SHOWING EPIDEMILOGICAL STUDYS OF THIS
COMMON COMPOUND.
Effects of Overexposure:SULFURIC ACID CAUSES SEVERE BURNS ON
CONTACT,ALL BODY TISSUES. LEAD INHALED OR INGESTED PRODUCTS
SYSTEMIC POISONING. HYDROGEN POSES NO TOXIC HAZARD.
Medical Cond Aggravated by Exposure:NONE.
First Aid
First Aid:SULFUR ACID CONTACT: EYE:FLUSH WITH WATER 15 MIN. SKIN:WASH
IMMEDIATELY WITH SOAP & WATER. INGESTED:DRINK LARGE QUANTITIES OF
MILK OR WATER. GET MEDICAL ATTENTION IF ANY PART IS INGESTED (LEAD
OR ACID ) OR IF BURNS ARE APPARENT OR EYE CONTACT OCCURS.
Fire Fighting
Flash Point:NONE
Extinguishing Media:CARBON DIOXIDE,DRY CHEMICAL,FOAM,WATER FOG.
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:PRODUCES HYDROGEN GAS DURING CHARGE
CYCLE. EXPLOSION HAZARD.
Accidental Release
Spill Release Procedures:ACID SPILL:NEUTRALIZE THEN FLUSH TO DRAIN.
Neutralizing Agent:SODIUM BICARBONATE OR 50/50 SODA ASH/LIME.
Handling
Handling and Storage Precautions:STORE IN A COOL,DRY,WELL VENTILATED
AREA.
Other Precautions:DO NOT CRACK CASE. DO NOT OVERCHARGE. DO NOT SHORT
CIRCUIT TERMINALS. KEEP IGNITION SOURCES AWAY FROM CHARGING
BATTERIES.
Exposure Controls
Respiratory Protection:NONE EXPECTED TO BE NECESSARY.
Ventilation:NORMAL ROOM VENTILATION. LOCAL EXHAUST OR SIMILAR WHEN
CHARGING.
Protective Gloves:RUBBER,WHEN HANDLING ELECTROLYTE.
Eye Protection:SPLASH GOGGLES WHEN HANDLING ELECTROLYTE
Work Hygienic Practices:USE GOOD INDUSTRIAL HYGIENE PRACTICE. AVOID
UNNECESSARY CONTACT.
Supplemental Safety and Health
Chemical Properties
HCC:N1
Stability
Stability Indicator/Materials to Avoid:YES
SOLVENTS WHICH DISSOLVE BATTERY CASE.
Stability Condition to Avoid:IGNITION SOURCES (ESPECIALLY SPARKS)
ESPECIALLY DURING CHARCH CYCLE.
Hazardous Decomposition Products:HYDROGEN,SULFUR DIOXIDE.
Disposal
Waste Disposal Methods:DISPOSE I/A/W FEDERAL,STATE,LOCAL REGULATIONS.
HMIS:NEUTRALIZE ACID & FLUSH TO DRAIN. RECYCLE REMAINDER BY SENDING
TO AUTO BATTERY RECOVERY FIRM. DO NOT INCINERATE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.